2K-Dispensing

2K-Electro-valves

Info

Our Electro-valve as a 2K-dispenser head is highly suitable for electronical precise dispensing of Two-components media out of 2K-double cartridges  - the problems of pneumatical controlled valves are avoided that can´t achieve the precision of step-motors.

Details

The media of those double-cartridges are mixed in a static mixing tube according of relevant ratios.
The geometry of the double cartridges hereby determines the mixing ratio.
By now the cartridges are offered in mixing ratios of 1:1, 1:2, 1:4 und 1:10, where the special size (e.g. 50 ml) only can be dispensed with the according valve (here Art.No. 4042 E50).

By using 2-component cartridges you can avoid the partly problematic handling of certain media that hardening time after mixing can be situated in a few minutes only.

4042 Electro-valve E50

- Clap-mechanism for cartridge replacement
- Duo-cartridge size: 50 ml
- Dispensing accuracy: +/- 0,02 ml (Material depending)
- Dispensing volume 0,05 - 0,5 ml/s
- Mixing ratio 1:1 / 1:2 / 1:4 / 1:10
- Weight ca. 3 kg
- Max. viscosity 80.000 mPas
- Size ca. 430 x 110 x 70 mm

PDF icon

4050 Electro-valve E200

- Duo-cartridge size: 200 ml
- Dispensing accuracy: +/- 0,1 ml (Material depending)
- Dispensing volume: 0,1 - 2 ml/s
- Mixing ratio: 1:1 / 1:2 / 1:4 / 1:10
- Weight: ca. 4,5 kg
- Max. viscosity: 80.000 mPas
- Size ca. 430 x 110 x 80 mm

PDF icon

4087 Electro-valve E400

- Duo-cartridge size: 400 ml
- Dispensing accuracy: +/- 0,4 ml (Material depending)
- Dispensing volume 0,4 - 2 ml/s
- Mixing ratio 1:1 / 1:2 / 1:4 / 1:10
- Weight ca. 5 kg
- Max. viscosity 120.000 mPas
- Size ca. 497 x 174 x 100 mm
PDF icon

4073_E2x310

4073 Electro-valve E2x310

- Duo-cartridge size: 2 x 310 ml
- Dispensing accuracy: +/- 0,2 ml (Material depending)
- Dispensing volume 0,2 - 2 ml/s
- Mixing ratio is free to choose
- Weight ca. 6 kg
- Max. viscosity 120.000 mPas
- Size ca. 610 x 140 x 80 mm
PDF icon

4029 1K-Electro valve

- Cartridge size: 1ml
- Dispensing accuracy: +/- 0,01 ml (Material depending)
- Dispensing volume: 0,02 - 0,5 ml/s
- Max. viscosity: 80.000 mPas
- Gewicht: ca. 500 g
- Size ca. 190 x 50 x 47 mm
PDF icon

4032 1K/2K-Electro-valve

- Using 1K-Media cartridge by replacing cartridge block
- Dispensing accuracy: +/- 0,01 ml (Material depending)
- Dispensing volume 0,05 - 0,5 ml/s
- Possible Mixing ratio 1:1 / 4:1/ 11:1
- Weight ca. 1000 g
- Max. viscosity 80.000 mPas
- Size ca. 250x 62 x 60mm
PDF icon

2K-Electro-valves with heating

4054 Electro-valve E200 Heating

- Duo-cartridge size: 200 ml
- Dispensing accuracy: +/- 0,1 ml (Material depending)
- Dispensing volume: 0,1 - 2 ml/s
- Mixing ratio: 1:1 / 1:2 / 1:4 / 1:10
- Weight: ca. 4,5 kg
- Max. viscosity: 120.000 mPas
- Heating block: Heatable up to 80°C (advised)
- Size ca. 430 x 110 x 80 mm
PDF icon

4086 Electro-valve E400 Heating

- Duo-cartridge size: 400 ml
- Dispensing accuracy: +/- 0,4 ml (Material depending)
- Dispensing volume: 0,4 - 2 ml/s
- Mixing ratio: 1:10
- Weight: ca. 5 kg
- Max. viscosity: 120.000 mPas
- Heating block: Heatable up to 100°C
- Size ca. 690 x 174 x 126 mm
PDF icon

2K-Electro-valves with absolute way-meter-system

 

4088 Electro-valve E400 WMS

- Duo-cartridge size: 400 ml
- Dispensing accuracy: +/- 0,4 ml (Material depending)
- Dispensing volume: 0,4 - 2 ml/s
- Mixing ratio: 1:1/ 1:2/ 1:4/ 1:10
- Weight: ca. 5 kg
- Max. viscosity: 120.000 mPas
- The absolute way-meter-system permanently outputs the actual piston position
- Size ca. 513 x 174 x 100 mm
PDF icon

2K-Gear pump


4300 2K-Gear pump

- Suitable for 2K-media from lowest to highest viscosity
- Suitable for 200 ml/ 400 ml DUO-cartridges
- Possible Mixing ratio and total volume per second and rotation:
  M 1:1 = 1,2 ml/Rot.
  M 1:2 = 0,9 ml/Rot.
  M 1:10 = 0,66 ml/Rot.
- Adjustable time interval for automatical purging
- External start via N/O contact
- Parameter settings by Software or Controller
PDF icon

Info

The deployment of a 2K-gear pump is useful for all operations you have to dispense 2K-media out of 200 ml or 400 ml DUO-cartridges with high volume accuracy.
Two separate gear pumps are operated with a single motor by connection shaft.
The mixing ratio is determined by pump volume, so there are three mixing ratios possible.
The discharging of the pump can be set.
The pre-set volume will be dispensed, then the gear pump is automatically stopped.
It also can be switched on and off with an external pushbutton.

2K-Volume dispensing

4031 Volume dispenser

- Drive by 18 bis 24V DC Incremental encoder, planetary gear
- Charging 0,14 ml/ Rotation
- Material inlet 1/4" Cylindrical Whitworth pipe thread
- Material outlet: Static mixing tube
- Weight: ca. 1600 g (without motor)
- Smallest dispensing volume (Shot) 0,03 ml
- Dispensing accuracy +/- 1% (material depending)
- Mixing relations 1:1 bis 5:1
PDF icon

Info

Volume dispensing of low to high viscous media by eccentric screw.
Material protecting charging with a volume accuracy of ca. 1%
Suitable for dispensing of UV-media, silicones, glues, greases but even abrasive media.

Kommentare sind geschlossen.